Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2020-07-17 to 2020-07-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D-445 (Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.481
Temp.:
40°C
Remarks on result:
not determinable
Remarks:
Test item is too volatile.
Conclusions:
The kinematic viscosity of the test item was determined to be 0.4807 mm²/s at 20 °C.
Executive summary:

A study was conducted according to ASTM D445 to determine the viscosity of the test item. The kinematic viscosity of the test item was determined to be 0.4807 mm²/s at 20 °C. The viscosity at 40 °C could not be determined because of the volatility of the test item.

Description of key information

The kinematic viscosity of the test item was determined to be 0.4807 mm²/s at 20 °C.

Key value for chemical safety assessment

Viscosity:
0.481 mm²/s (static)
at the temperature of:
20 °C

Additional information

A study was conducted according to ASTM D445 to determine the viscosity of the test item. The kinematic viscosity of the test item was determined to be 0.4807 mm²/s at 20 °C. The viscosity at 40 °C could not be determined because of the volatility of the test item.