Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 13 2020 - October 13 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
Not specified.
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
4 min
Moisture (wt %):
48
Remarks on result:
other:
Remarks:
The ignition of test item was observed, but the burning of test item did not propagated 200 mm length of the powder train for 4 minutes.
Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined to be not highly flammable.
Executive summary:

The objection of this study is to evaluate the flammability of Dye-2019.The study was carried out in accordance with EU test guideline A.10. in compliance with GLP.

The preliminary screening test was performed at room temperature (25°C) at an indoor humidity of 48%. Ignition of the test item was observed, but the burning of the test item did not propagate 200 mm length of the powder train for 4 minutes. The test item was determined not to be highly flammable.

Description of key information

The test item was determined to be not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Ignition of the test item was observed, but the burning of the test item did not propagate 200 mm length of the powder train for 4 minutes. The test item was determined not to be highly flammable.