Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is marketed or used in a non solid or granular form
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
no guideline followed
Principles of method if other than guideline:
1. Upon receiving material samples, visually check top and bottom (on liquid products only) samples for haze, particulate matter, or discoloration.
2. If material is not perfectly clear or free of particulate matter, request a resample. Also, compare sample to a retain of the previous receipt.
3. If any doubt persists, the material is vacuum filtered through a clean Whatman #4 filter paper inserted into a clean & dry Buchner funnel. There should be no particulate matter observed on the filter paper.
4. If after resampling, the material does not meet visual clarity specification, inform the Lab Manager or Lab Supervisor and the Shift Supervisor that the material is rejected due to physical appearance.
5. If the material is rejected due to physical appearance, file the appropriate report:
a. Raw Material Non-Conformance
A Vendor Corrective Action report will be initiated and sent to the vendor for completion.
b. Finished Product/Intermediate Non-Conformance
A Non-conformance report will be initiated and sent to management for review.
GLP compliance:
no
Physical state at 20°C and 1013 hPa:
liquid
Form:
liquid
Colour:
pale
Substance type:
organic
Conclusions:
Substance is liquid at 25C and 1013 hPa
Executive summary:

Substance is liquid at 25C and 1013 hPa