Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-6-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: BS ISO 13320-1:1999
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
not specified
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
not specified
GLP compliance:
yes
Type of method:
other: Optical microscope analysis and Laser diffraction particle size analysis
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
74.395 µm
St. dev.:
0.78

Test results (in μm):

 

Run 1

Run 2

Run 3

Run 4

Run 5

* Average

Volume weighted mean

84.998

84.617

112.580

109.384

91.332

96.582

Median (d. 50)

73.967

73.626

75.100

75.574

73.768

74.395

Mode (μm)

76.908

76.520

76.677

77.288

76.372

75.749

10 % of material is <

33.517

33.569

34.156

33.950

33.396

33.715

50 % of material is <

73.967

73.626

75.100

75.574

73.768

74.395

90 % of material is <

148.059

146.765

157.421

158.861

149.441

151.807

* Average result is calculated from the entirety of data captured in each run and is not a simple arithmetic mean.

1.48 % by volume of sample was seen to be < 10.00 μm.

Standard deviation results:

 

Run 1

Run 2

Run 3

Run 4

Run 5

Stdev

%STDV

D10

33.517

33.569

34.156

33.950

33.396

0.29

0.85

D50

73.967

73.626

75.521

75.574

73.768

0.78

1.05

D90

148.059

146.765

157.521

158.861

149.441

5.04

3.31

D15.78

2.750

2.710

2.590

2.720

2.740

0.06

2.14

GSD

26.897

27.168

28.996

27.785

26.923

0.79

2.86

GSD = Geometric standard deviation.

Coefficient of variation for d50 was less than 3 %; d10 and d90 were less than 5 %. Therefore repeatability of the characteristic particles in the size distribution were within the acceptable limits as per the BS ISO 13320 -1 test standard.

Conclusions:
Coefficient of variation for d50 was less than 3 %; d10 and d90 were less than 5 %. Therefore repeatability of the characteristic particles in the size distribution were within the acceptable limits as per the BS ISO 13320 -1 test standard.
Executive summary:

A study performed according to GLP, BS ISO 13320-1:1999 and CIPAC MT 187; and equivalent to OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) gave a mean d50 of boric acid of 74.395 μm.

Description of key information

A study performed according to GLP, BS ISO 13320-1:1999 and CIPAC MT 187; and equivalent to OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) gave a mean d50 of boric acid of 74.395 μm.

Additional information