Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

There was no inhibition of activated sludge at any of the concentrations of Silicon Nitride tested. Therefore EC50 was >300 mg/L.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
300 mg/L

Additional information

An Activated Sludge Respiration Inhibition Test (ASRIT) was conducted (ARC Seibersdorf research GmbH, 2005) to determine the effect of Silicon Nitride on microorganisms. The test was conducted according to OECD test guideline 209, EC Directive 87/302 (method C11), and in compliance with GLP. Activated sludge was taken from a sewage treatment plant which treated predominantly domestic waste. Cultures were exposed to Silicon Nitride at concentrations of 7.0, 16.0, 47.2, 118.8, 303.8 and 304.4 mg/L. There was no inhibition of the activated sludge at any of the test substance concentrations. The respiration rates of all samples with the test substance were in the range of 97.1 to 105.8% of the control value.

EC20 >300 mg/L

EC50 >300 mg/L

EC80 >300 mg/L