Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 21 - April 22, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Version / remarks:
European Commission Regulation (EC) No 440/2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
> 6.5
Temp.:
25 °C
Remarks on result:
other: no pH value indicated

The log Pow of the test item wa above the highest log Pow (6.5) value of calibration substances (4,4'-DDT). The log Pow value of the test item was calculated to be 10.6 via extrapolation.

Conclusions:
The partition coefficient n-octanol/water of the test item was determined according to the HPLC method described in the European Commission Regulation (EC) No 440/2008. The log Pow value of the test item was greater than 6.5 and thus above the highest log Pow value of calibration substances.

Description of key information

The partition coefficient n-octanol/water of the test item was determined according to the HPLC method described in the European Commission Regulation (EC) No 440/2008. The log Pow value of the test item was greater than 6.5 and thus above the highest log Pow value of calibration substances.

Key value for chemical safety assessment

Additional information