Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 27 February and 6 March 2014.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Specific details on test material used for the study:
Aspect: Yellow viscous liquid
Lot No.: VE00313054
Flash point:
153 °C
Atm. press.:
101 325 Pa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Aurantiol Pure was determined to be 153°C.
Executive summary:

The flash point of Aurantiol Pure was determined using the Pensky-Martens method according to Method A.9 of EC Council Regulation No 440/2008.

The flash point of Aurantiol Pure was determined to be 153°C.

Description of key information

The flash point was 153 °C using a closed cup equilibrium method designed to be compatible with Method A9 Flash Point of Commission Regulation (EC) No. 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
153 °C

Additional information