Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 Aug - 12 Aug 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hessisches Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Chemical structure
Reference substance name:
1-(2,2,4-trimethyl-3,4-dihydroquinolin-l (2H)-yl)ethanone
EC Number:
855-228-0
Cas Number:
4497-59-0
Molecular formula:
C14 H19 N O
IUPAC Name:
1-(2,2,4-trimethyl-3,4-dihydroquinolin-l (2H)-yl)ethanone

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 hPa
Remarks on result:
other: extrapolated from the experimental data (vapour pressure: effusion method)
Temp.:
25 °C
Vapour pressure:
0 hPa
Remarks on result:
other: interpolated from the experimental data (vapour pressure: effusion method)
Vapour pressure at 50°C (if relevant for classification of gas under pressure)
Vapour pressure:
0.009 hPa
Remarks on result:
other: interpolated from the experimental data (vapour pressure: effusion method)

Any other information on results incl. tables

Individual results
The vapour pressure was measured in the temperature range of 25 °C to 60 °C. The measured vapour pressures at the corresponding temperatures are listed in the Table below. After the measurement a mass loss of approx. 100 % (w/w) was determined.





























Temperature / °CVapour Pressure /hPa
254.1 x 10-4
455.3 x 10-3
508.7 x 10-3
551.5 x 10-2
60n.e. (not evaluable)

No data point could be measured at 60 °C because at this temperature the test item evaporated completely from the crucible. 


From the measured data the parameters A, B and C of the Antoine equation can be derived by regression.


log(p/ hPa) = A + (B/ (C + T C]))


 


The evaluated Antoine parameters are listed in the Table below.

















A13.68092
B-5086.68
C273.15

The vapour pressure values for 20, 25 and 50 °C (see Table below) were interpolated (values at 25 °C and 50 °C) and extrapolated (value at 20 °C), using these Antoine constants AB and C.

























T /°Cp /hPap /Pa
202.1 x 10-42.1 x 10-2
254.2 x 10-44.2 x 10-2
508.7 x 10-38.7x 10-1

 

Applicant's summary and conclusion