Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Remarks:
Other density types indicated (migrated information): density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected: June 2015; signature: September 2015
Type of method:
pycnometer method
Type:
relative density
Density:
0.942
Temp.:
20 °C
Remarks on result:
other: mean relative density; Temperature: ± 0.5°C
Type:
density
Density:
942 kg/m³
Temp.:
20 °C
Remarks on result:
other: mean density; Temperature: ± 0.5°C

Table 1.0 – Pycnometer method determinations

Measurement

Determination

1

2

Mass of pycnometer (g)

18.2211

17.3532

Mass of pycnometer and purified water at 20.4 °C (g)

28.1392

27.5640

Mass of pycnometer and test item at 19.8 °C (g)

27.5756

26.9910

Density of water at 20.4 °C (kg/m3)

998.12

998.12

Density (kg/m3)

941.4

942.1

Relative density

0.9414

0.9421

 

Mean density: 942 kg/m3
Mean relative density: 0.942

Temperature: 20.0 ± 0.5 °C

Conclusions:
The density of the test substance has been determined to be 942 kg/m^3 at 20 ± 0.5 °C using the pycnometer method.
Executive summary:

The density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean density (n=2) of the test substance has been determined to be 942 kg/m^3 at 20 ± 0.5 °C. The relative density was 0.942.

Description of key information

Relative Density: 0.942 at 20 ± 0.5 °C, EU Method A.3 pycnometer method, 2016

Key value for chemical safety assessment

Relative density at 20C:
0.942

Additional information

Key study: EU Method A.3, 2016 : The density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean density (n=2) of the test substance has been determined to be 942 kg/m^3 at 20 ± 0.5 °C. The relative density was 0.942.