Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 December 2017 to 01 June 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: isothermal thermogravimetry
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
0 Pa

For runs 1 to 3, there were initial high weight losses at lower temperatures. This was indicative of degassing of the sample, so the data from run 4 was used. A fresh sample was then used for runs 5 and 6. There was initial degassing in the first of these runs, so the data from run 6 was also used. The data from runs 4 and 6 were therefore used for calculations.

Table 1- Summary of results from runs 4 and 6

Parameter

Run 4

Run 6

Correlation (R2)

0.9428

0.9656

Slope

-4042

-3345

Intercept

9.551

7.933

log10PTat 25°C

-4.0

-3.3

PT(Pa) at 25°C

9.9 x 10-5

5.2 x 10-4

 

Table 2- Vapour pressure measurements (Run 4)

Temperature
(°C)

Evaporation rate,VT
(g/minute)

log10VT

log10PT

138.57

0.0000002689

-4.085

-0.3611

148.53

0.0000006267

-3.718

0.03205

158.48

0.000001069

-3.486

0.2802

168.44

0.000001428

-3.360

0.4148

178.41

0.000001801

-3.259

0.5226

 

Table 3- Vapour pressure measurements (Run 6)

Temperature
(°C)

Evaporation rate,VT
(g/minute)

log10VT

log10PT

138.37

0.0000003367

-3.988

-0.2567

148.33

0.0000006363

-3.711

0.03912

158.29

0.0000009727

-3.527

0.2363

168.27

0.000001291

-3.404

0.3679

178.24

0.000001614

-3.307

0.4717

 

Conclusions:
The vapour pressure of the test item was determined to be 0.0003 Pa at 25°C.
Executive summary:

The vapour pressure of the test item was determined in a study following OECD 104 and EC Method A4 guidelines, by the effusion method using isothermal thermogravimetry analysis. The vapour pressure of the test item was determined to be 3 x 10-4 Pa at 25°C.

The study is a GLP-compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The vapour pressure of the test item was determined to be 0.0003 Pa at 25°C.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

The vapour pressure of the test item was determined in a study following OECD 104 and EC Method A4 guidelines, by the effusion method using isothermal thermogravimetry analysis (Dunning 2018). The vapour pressure of the test item was determined to be 3 x 10-4 Pa at 25°C.

The study is a GLP-compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.