Administrative data

Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 14, 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D 92 for flash and fire points
Deviations:
no
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Anton Paar Model CLA 5 Automatic Cleveland Flash & Fire Point Tester
Key result
Flash point:
242 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 242C
Executive summary:

Flash point is 242C using equivalent test method to ASTM D92

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14/08/2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
other: USP-NF method <741>
GLP compliance:
no
Type of method:
capillary method
Key result
Melting / freezing pt.:
68 °C
Atm. press.:
1 013 hPa
Conclusions:
Meltiing point is 68C at 1013 hPa
Executive summary:

Melting point is 68C at 1013 hPa using test method based on USP-NF method <741>.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion