Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, acceptable without restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
yes
Remarks:
Due to the limited amount of test item available the pile was only 160mm long not 250mm as detailed in the method.
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Pile failed to ignite during the five minutes that the Bunsen flame was applied.

Pile failed to ignite during the five minutes that the Bunsen flame was applied.

Interpretation of results:
GHS criteria not met
Conclusions:
Platinum is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. Platinum is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Description of key information

Platinum is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The result is from a GLP compliant study following a modified N1 method for self-heating substances and is considered suitable for use as the key study for this endpoint (Atwal and Tremain 2011). Platinum is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.