Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
84/449/EWG, A.1 (Kapillar-Methode, Metallblock)
GLP compliance:
yes
Type of method:
capillary method
Melting / freezing pt.:
> 390 °C
Decomp. temp.:
> 390 °C

decomposition before melting.


Up to the highest tested temperature of 390 °C, no melting observed.

Conclusions:
decomposition before melting.
Up to the highest tested temperature of 390 °C, no
melting observed.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion

Conclusions:
According to the Annex VII of the REACH Regulation (EC 1907/2006), the study on vapour pressure does not need to be conducted if the melting point is above 300 °C.
The decomposition of the test item is starting at around 390 °C.