Endpoint:
auto-ignition temperature (liquids)
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Version / remarks:
2005
Deviations:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
The tested substance has the same light constituents, even in higher quantity in respect to the substance Hydrocarbons, C10-C14, n-alkanes, <2% aromatics, therefore the auto ignition temperature of tested substance is representative of Hydrocarbons, C10-C14, n-alkanes, <2% aromatics
Key result
Auto-ignition temperature:
210 °C
Atm. press.:
101.5 kPa
Conclusions:
The auto ignition temperature of the tested substance has been measured following the ASTM E 659-78 (2005) method. The result is 210°C. at 101.5 kPa
Executive summary:

The auto ignition temperature  of the tested substance has been measured following the ASTM E 659-78 (2005) method. The result is 210°C. at 101.5 kPa

Description of key information

There is no data available for Hydrocarbons, C10-C14, n-alkanes, <2% aromatics. However, data is available for structural analogue Hydrocarbons, C10-C13, n-alkanes, <2% aromatics and presented in the dossier. This data is read across to Hydrocarbons, C10-C14, n-alkanes, <2% aromatics based on analogue read across. A discussion and report on the read across strategy is provided as an attachment in IUCLID Section 13.

The Auto Ignition Temperature of the substance Hydrocarbons, C10-C13, n-alkanes, <2% aromatics is 210°C at 101.5kPa

Key value for chemical safety assessment