Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 April 2017 - 18 October 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Version / remarks:
2001
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil

Test material

Constituent 1
Chemical structure
Reference substance name:
Aluminium tribenzoate
EC Number:
209-091-3
EC Name:
Aluminium tribenzoate
Cas Number:
555-32-8
Molecular formula:
C7H6O2.1/3Al
IUPAC Name:
aluminium tribenzoate
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): Aluminium tribenzoate
- Appearance: white powder
- Storage conditions: at room temperature
Radiolabelling:
no

Study design

Test temperature:
Column temperature: 35°C ± 1°C

HPLC method

Details on study design: HPLC method:
PKA CALCULATION
pKa acidic: 4.2 pKa basic: none (Perrin calculation method for the logarithm range of 1 - 14, pKalc 5.0, module in Pallas 3.0, CompuDrug International, USA).

HPLC CONDITIONS
- Apparatus: Acquity UPLC system (Waters, USA)
- Column: Acquity UPLC HSS Cyano, 100 mm x 2.1 mm i.d., dp = 1.8 µm (Waters)
- Injection volume: 5 μL
- Detector: Acquity UPLC TUV (Waters)
- UV detection: 210 nm

MOBILE PHASE
- Since the test item is a salt, the test was performed with no buffer
- Type: unbuffered mobile phase
- Composition: 55/45 (v/v) methanol/water
- Flow: 0.4 mL/min

REFERENCE ITEMS
- Identity: Acetanilide (log Koc = 1.26 according to OECD 121 based on soil absorption data).
- Solution of the reference item was prepared in 55/45 (v/v) methanol/water from a stock solution (ca. 1 g/L) in methanol.

TEST ITEM
- A 10 mg/L test item solution was prepared in 55/45 (v/v) methanol/water from a stock solution (1000 mg/L) in //methanol.
- The stock solution was ultrasonicated for one minute.

DETERMINATION OF RETENTION TIMES
- Duplicate injections of the reference item and test item.
- Single injection of the blank (55/45 (v/v) methanol/water).

Results and discussion

Adsorption coefficientopen allclose all
Key result
Type:
log Koc
Value:
< 1.26 dimensionless
Temp.:
20 °C
Remarks on result:
other: Unbuffered mobile phase
Key result
Type:
Koc
Value:
< 18.2 L/kg
Temp.:
20 °C
Remarks on result:
other: Unbuffered mobile phase

Results: HPLC method

Details on results (HPLC method):
Mean retention time of the reference item: 0.905 minutes
Mean retention time of the test item: 0.784 minutes

Any other information on results incl. tables

See Illustration for Chromatogram

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The log Koc of the substance at neutral pH was estimated to be < 1.26 (Koc < 18.2).

Executive summary:

The HPLC estimation method based on soil-adsorption reference data was used for the determination of the adsorption coefficient (Koc) of the substance. The study was performed in accordance with EC C.19 and OECD 121 and in compliance with GLP. The unbuffered mobile phase was 55/45 (v/v) methanol/water and the wavelength of detection was 210 nm. The stationary phase contained cyanopropyl chains chemically bonded to silica. One reference item was used: Acetanilide (log Koc 1.26 based on soil-adsorption reference data). Duplicate injections of the reference substance and test item. Mean retention time of the reference item: 0.905 minutes Mean retention time of the test item: 0.784 minutes. From this it was concluded that the log Koc of the substance is < 1.26 (Koc < 18.2).