Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 15 to 19 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 1700001575
- Expiration date of the lot/batch: 09.08.2020
- Manufacturing date: 10.08.2017
Test procedure:
burning rate test: preliminary screening test
Remarks:
The test item could not be ignited and no smouldering was observed.
Burning time:
> 120 s
Moisture (wt %):
38
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
Preliminary Testing > 120 s. The combustion is interrupted < 200 mm. No further testing is necessary.
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The flammability of the test item was determined following ONU Test N.1 (Flammability of solids).
During a preliminary testing < 120 second, the combustion is stopped before < 200 mm. As the test item could not be ignited in the preliminary test, no further testing of the burning rate was required.
Therefore, the test item is considered to be not flammable according to CLP criteria.

Description of key information

The flammability of the test item was determined following ONU Test N.1 (Flammability of solids).

During a preliminary testing < 120 second, the combustion is stopped before < 200 mm. As the test item could not be ignited in the preliminary test, no further testing of the burning rate was required.

Therefore, the test item is considered to be not flammable according to CLP criteria.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

As the test item could not be ignited in the preliminary test following ONU Test N.1 (Flammability of solids),

no further testing of the burning rate was required.

Therefore, the test item is considered to be not flammable according to CLP criteria.