Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
experimental dates: 27 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
02. Oct. 2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
Regulation (EC) No 440/2008 of 30. May 2008
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
Landesamt für Umwelt, Wasserwirtschaft und Gewerbeaufsicht (inspected on 13 & 14 October 2014, 2010 / signed on 08 April 2015)
Type of method:
pycnometer method
Specific details on test material used for the study:
Storage conditions of test material: The test item was stored in a metal bottle as received in the dark from the day of receipt till the 18. Jan. 2017 at 17.2 °C – 21.5 °C and was then stored in a closed vessel (original metal bottle) at 3.0 °C – 8.0 °C in the dark.
Dynamic viscosity of test material:
flowable (˂ 500 Pa.s)
Key result
Type:
density
Density:
0.865 g/cm³
Temp.:
20 °C
Type:
relative density
Density:
0.865 other: relative density is unitless
Temp.:
20 °C

Table 4.4/1: Calculated Values

 

First Determination

 

 

Error rel.

Error abs.

Temperature

20.0

°C

 

0.1

Density of water

0.998203

g/cm3

2.00%

0.0002

Volume of Pycnometer

9.9335

cm3

 

 

Density of Test Item

0.8649

g/cm3

0.0130%

0.0001

Second Determination

 

 

Error rel.

Error abs.

Temperature

20.2

°C

 

0.1

Density of water

0.998203

g/cm3

2.00%

0.0002

Volume of Pycnometer

9.9337

cm3

 

 

Density of Test Item

0.8649

g/cm3

0.0130%

0.0001

 

Table 4.4/2: Results of Single Determinations

 

Determination

Density in g/cm3

Error of Determ. in g/cm3

1

0.8649

0.0001

2

0.8649

0.0001

 

Table 4.4/3: Results – Mean Values

 

Parameter

Value

Unit

Standard Deviation

Relative Standard Deviation

Volume of Pycnometer

9.93

cm3

0.0001

0.00 %

Density of Test Item

0.8649

g/cm3

0.0000

0.00 %

Density of Test Item

864.9

kg/m3

0.0

0.00 %

Relative Density of Test Item

0.8649

 

0.0000

0.00 %

Conclusions:
The substance is much less dense than water.
Executive summary:

The density of the test substance was measured under GLP according OECD 109 / EU A3 guideline, pycnometer method.

Experiment was performed at 20 °C in duplicate, and the mean density was calculated.

A density of 0.8649 ± 0.0001 g/cm3 at 20 ± 0.2 °C was measured. This value is the mean of two independent determinations with the maximum error of a single determination. Standard deviation was 0.0000 g/cm3, showing perfect correlation of the two determinations.

The relative density (D20/4) of the test substance was calculated to be 0.8649.

Description of key information

The substance is much less dense than water.

Key value for chemical safety assessment

Relative density at 20C:
0.865

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EC method and under GLP, is available. It is considered as a key study. The result is retained as key data.

Note that this parameter may show some variations, due to the UVCB nature of the substance.