Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 481-150-8 | CAS number: 500011-86-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study completed under GLP according to OECD 107.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 006
- Report date:
- 2006
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- Remarks:
- The study was conducted according to the guideline in effect at time of study conduct.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- no
- Remarks:
- The study was conducted according to the guideline in effect at time of study conduct.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- -
- EC Number:
- 481-150-8
- EC Name:
- -
- Cas Number:
- 500011-86-9
- Molecular formula:
- C9H5BrClN3O2
- IUPAC Name:
- 3-bromo-1-(3-chloropyridin-2-yl)-1H-pyrazole-5-carboxylic acid
- Reference substance name:
- 1H-Pyrazole-5-Carboxylic Acid, 3-Bromo-1-(3-Chloro-2-Pyridinyl)-
- IUPAC Name:
- 1H-Pyrazole-5-Carboxylic Acid, 3-Bromo-1-(3-Chloro-2-Pyridinyl)-
- Reference substance name:
- DBC 80
- IUPAC Name:
- DBC 80
- Details on test material:
- - Name of test material (as cited in study report): IN-DBC80
- Molecular weight: 302.52
- Physical state: Tan colour powder
- Analytical purity: 96.7%
- Lot/batch No.: 008
- Expiration date of the lot/batch: 22nd July, 2008
- Storage condition of test material: Stored in the dark at room temperature (ambient
<25 degrees Celcius).
Constituent 1
Constituent 2
Constituent 3
Study design
- Analytical method:
- high-performance liquid chromatography
Results and discussion
Partition coefficientopen allclose all
- Type:
- Pow
- Partition coefficient:
- ca. 0.53
- Temp.:
- 23 °C
- Type:
- Pow
- Partition coefficient:
- ca. -0.68
- Temp.:
- 23 °C
- pH:
- 4
- Type:
- Pow
- Partition coefficient:
- ca. -1.49
- Temp.:
- 23 °C
- pH:
- 7
- Type:
- Pow
- Partition coefficient:
- ca. -1.59
- Temp.:
- 23 °C
- pH:
- 9
- Details on results:
- Partition coefficient of IN-DBC80 determined in Milli Q water was 0.53 +/- 0.05 at 23 +/- 1 deg C
Partition coefficient of IN-DBC80 determined in pH 4.0 buffer was -0.68 +/- 0.05 at 23 +/- 1 deg C
Partition coefficient of IN-DBC80 determined in pH 7.0 buffer was -1.49 +/- 0.11 at 23 +/- 1 deg C
Partition coefficient of IN-DBC80 determined in pH 9.0 buffer was -1.59 +/- 0.11 at 23 +/- 1 deg C
Any other information on results incl. tables
Linearity of Response Results: A plot of the found peak area of IN-DBC80 vs. the concentration of IN-DBC80 in the samples showed acceptable linearity, as indicated by the correlation coefficient of 0.9996.
System Precision Results: The coefficient of variation for the 10 determined peak areas was 1.43%, which shows an acceptable system precision.
Assay Accuracy and Assay Precision Results: Multiple recovery control samples (n=6) at each of 2 fortification levels equivalent to 109.06 ug/mL and 1023.3 ug/mL IN-DBC80 in final solution were assayed using HPLC conditions consistent with study conditions. The overall assay accuracy of 95.12% and precision RSD of 1.67% indicated an acceptable method of analysis in low concentration. The overall assay accuracy of 96.68% and precision RSD of 1.20% indicated an acceptable method of analysis in high concentration.
Method Specificity Results: No significant interference was observed from the Milli-Q water, n-octanol, and pH 4.0, 7.0 and 9.0 buffer samples.
Applicant's summary and conclusion
- Conclusions:
- The mean partition coefficient values of IN-DBC80 at 23 +/- 1 degree Celcius were determined to be 0.53 +/- 0.05 in Milli Q water, -0.68 +/- 0.05 in pH 4.0 buffer, -1.49 +/- 0.11 in pH 7.0 buffer, and -1.59 +/- 0.11 in pH 9.0 buffer. The water solubility study conducted on IN-DBC80 showed an increase in the water solubility with increasing pH. This is due to the acidic nature of IN-DBC80 and is also demonstrated as a decrease in the partition coefficient with increasing pH.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.