Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From May to June 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: CF02
- Expiration date of the lot/batch: 31.01.2019
- Purity test date: not available

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: refrigerated (2 to 8°C)
- Stability under test conditions: not available
- Solubility and stability of the test substance in the solvent/vehicle: not applicable
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: not applicable

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: none
- Preliminary purification step (if any): none
- Final dilution of a dissolved solid, stock liquid or gel: not applicable
- Final preparation of a solid: not applicable

OTHER SPECIFICS: none
Key result
Decomposition:
yes
Decomp. temp.:
> 102.21 °C

 

Endotherm onset temperature (ºC)

Heat of melting (J/g)

2nd Endotherm onset temperature (ºC)

Heat of decomposition (J/g)

Screening test

-16.94

79.668

102.21

1050.9

The first endothermic event was suspected to be melting temperature and the onset was at -16.94°C. The second endothermic event was suspected to be caused by moisture evaporation. However, the sample did not boil at this event. Sample decomposed with the onset temperature of >102.21 ºC.

Conclusions:
In a Diffential Scanning Calorimetry (DSC) test, conducted according to OECD test guideline 103 and to GLP, a decomposition temperature of >102.21°C was determined for Coffee, bean, roasted ext.
Executive summary:

A Diffential Scanning Calorimetry (DSC) test, conducted according to OECD test guideline 103 and to GLP, was performed to determine the boiling point and / or the onset temperature and magnitude of any exothermic activity for Coffee, bean, roasted, ext.

A sample of Coffee, bean, roasted, ext, was charged to an aluminium DSC crucible, which was then sealed and placed in the furnace. The sample was then ramped from -40ºC to 500ºC at 10 K/min.

A decomposition temperature of >102.21°C was determined for Coffee, bean, roasted, ext.

Description of key information

Boiling point: >102.21°C (decomposition temperature)

Key value for chemical safety assessment

Additional information

A Diffential Scanning Calorimetry (DSC) test, conducted according to OECD test guideline 103 and to GLP, was performed to determine the boiling point and / or the onset temperature and magnitude of any exothermic activity for Coffee, bean, roasted, ext.