Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21-07-2019 to 26-07-2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected: August 2018 ; signature: November 2018
Type of method:
pycnometer method
Type:
relative density
Density:
0.969 other: dimensionless
Temp.:
20 °C
Remarks on result:
other: mean relative density (n=2); Temperature: ± 0.5°C
Type:
density
Density:
969 kg/m³
Temp.:
20 °C
Remarks on result:
other: mean density (n=2); Temperature: ± 0.5°C

Table 1.0 – Pycnometer method determinations

Measurement

Determination

1

2

Mass of pycnometer (g)

17.6556

17.8628

Mass of pycnometer and purified water at 20.0 °C (g)

27.8654

28.0701

Mass of pycnometer and test item at 20.0 °C (g)

27.5678

27.7765

Density of water at 20.0 °C (kg/m3)

998.20

998.20

Density (kg/m3)

969

969

Relative density

0.969

0.969

 

Mean density: 969 kg/m3
Mean relative density: 0.969

Temperature: 20.0 ± 0.5 °C

Conclusions:
The density of the test item has been determined to be 969 kg/m^3 at 20 ± 0.5 °C using the pycnometer method.
Executive summary:

The density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean density (n=2) of the test item was determined to be 969 kg/m^3 at 20 ± 0.5 °C. The relative density was 0.969.

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 April 2021 - 14 April 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other:
Remarks:
Study conducted according to OECD 109 and EU A.3 guidelines, under GLP without deviation and with certificate of analysis included.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
not specified
GLP compliance:
yes
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
0.968
Temp.:
20 °C
Remarks on result:
other: final result (mean of the two determinations)
Key result
Type:
density
Density:
968.5 kg/m³
Temp.:
20 °C
Remarks on result:
other: final result (mean of the two determinations)

Results:


The results for duplicate determinations of density are shown in the following table:


 









































MeasurementDetermination
12
Constant mass of pycnometer (g)18.036218.0024
Mass of pycnometer and purified water at 20.0 °C (g)28.108028.0295
Mass of pycnometer and test item at 20.0 °C (g)27.807827.7311
Temperature of test item (°C)20.0
Density of water at 20.0 °C (kg/m3)998.2
Density of test item (kg/m3)968.5968.5

 


 


Mean density: 968.5 kg/m3


Relative density: 0.969


Temperature: 20.0 + 0.05 °C

Conclusions:
The density of the test item has been determined to be 968.5 kg/m3 at 20.0 ± 0.5 °C and a relative density of 0.969.
Executive summary:

The density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean density (n=2) of the test item was determined to be 968.5 kg/m^3 at 20 ± 0.5 °C. The relative density was 0.969.

Description of key information

Weight of evidence: Relative Density of substance : 0.969 at 20 ± 0.5 °C, 2020


1. Relative Density: 0.969 at 20 ± 0.5 °C, EU Method A.3 pycnometer method, 2019


2. Relative Density: 0.969 at 20.0 ± 0.5 °C, EU Method A.3 pycnometer method, 2021

Key value for chemical safety assessment

Relative density at 20C:
0.969

Additional information

Key study : EU Method A.3, 2019 : The density was determined according to EU Method A.3 and OECD TG 109 using the pycnometer method under GLP. The mean density (n=2) of the test item was determined to be 969 kg/m^3 at 20 ± 0.5 °C. The relative density was 0.969.