Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-06-13 (experimental phase)
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
in-house data with poorer documentation, but given data allows to conclude that the study was properly conducted

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
Pensky-Martens Closed Cup Method P2902, (DIN EN ISO 2719)
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

impurity 1
Reference substance name:
Phosphoric acid, butyl ester, branched, compd. with 2-ethyl-N-(2-ethylhexyl)-1-hexanamine
EC Number:
308-859-6
EC Name:
Phosphoric acid, butyl ester, branched, compd. with 2-ethyl-N-(2-ethylhexyl)-1-hexanamine
Cas Number:
98679-19-7
Molecular formula:
not applicable (UVCB substance)
IUPAC Name:
Phosphoric acid, butyl ester, branched, compd. with 2-ethyl-N-(2-ethylhexyl)-1-hexanamine
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
107.5 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Remarks:
EU implementation
Conclusions:
The study was performed according to DIN EN ISO 2719 with the Pensky-Martens closed cup method on the substance to be registered itself, the test procedure is sufficiently documented and therefore reliability of Klimisch 2 has been assigned. The flash point was determined to be 107.5°C at 101.3 kPa. Hence, it does not need to be regarded as flammable liquid according to Regulation 1272/2008, as it defines flammable liquid as a liquid having a flash point of not more than 60°C.
Executive summary:

The flash point was determined according to DIN EN ISO 2719 with the Pensky-Martens closed cup method to be 107.5°C at 101.3 kPa. The substance is not a flammable liquid according to Regulation 1272/2008.