Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-09-28- 2018-03-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
769.2 µm
St. dev.:
10.39

The test item EVANSTAB® 12/18 consists of a coarse fraction with particle sizes of >2000 µm of 92.6 % and a fine fraction with particle sizes of <2000 µm of 7.4%. The fine fraction of the test item has a median particle size D50 = 769 µm, which was determined by laser diffraction measurement.

Conclusions:
The test item EVANSTAB®12/18 consists of a coarse fraction with particle sizes of >2000 µm of 92.6% and a fine fraction with particle sizes of <2000 µm of 7.4%. The fine fraction of the test item has a median particle size D50 = 769 µm, which was determined by laser diffraction measurement.
Executive summary:

The test item EVANSTAB® 12/18 consists of a coarse fraction with particle sizes of >2000 µm of 92.6% and a fine fraction with particle sizes of <2000 µm of 7.4%. The fine fraction of the test item has a median particle size D50 = 769 µm, which was determined by laser diffraction measurement.