Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 06 December 2017 to 04 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
no self ignition observed under the test conditions

Applicant's summary and conclusion

Conclusions:
No endothermic or exothermic effect of the test item was observed between 19°C and 400°C. It demonstrated that the test item is not self-ignitable.
Executive summary:

The self-ignition temperature of Carrier FK-800 was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device.

Based on the results obtained the test item is considered ‘not self-ignitable’. After the experiment, the consistency of the sample was unchanged, i.e. no reaction and/or decomposition of the test item was observed.