Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
ASTM D6450 Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Tag apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
2-isopropyl-N,2,3-trimethylbutyramide
EC Number:
256-974-4
EC Name:
2-isopropyl-N,2,3-trimethylbutyramide
Cas Number:
51115-67-4
Molecular formula:
C10H21NO
IUPAC Name:
2-isopropyl-N,2,3-trimethylbutyramide
Test material form:
solid: particulate/powder

Results and discussion

Flash point
Key result
Flash point:
100 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item was measured according to the ISO 2719 method to be at 100 °C.
Executive summary:

The flash point of the test item was measured according to the ISO 2719 method to be at 100 °C.