Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
no data
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Results sufficiently described and documented.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Principles of method if other than guideline:
The particle size distribution of a sample of the test substance was performed using laser diffraction. A Malvern Master Sizer S was used. The sample was dispersed in deionized water and the solution was stirred mechanically and ultrasonically to guarantee homogenous dispersion of the particles.
GLP compliance:
not specified
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
nickel (II) oxalate dihydrate
IUPAC Name:
nickel (II) oxalate dihydrate
Constituent 2
Reference substance name:
6018-94-6
Cas Number:
6018-94-6
IUPAC Name:
6018-94-6
Details on test material:
- Name of test material (as cited in study report): nickel oxalate dihydrate
- Molecular formula (if other than submission substance): NiC2O4.2H2O
- Molecular weight (if other than submission substance): 182.7 g/mol
- Physical state: powder
- Analytical purity: no data
- Lot/batch No.: no data
- Expiration date of the lot/batch: no data
- Stability under test conditions: no data
- Storage condition of test material: at room temperature in the dark

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
11.72 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
other: D25
Mean:
> 23.62 - < 26.04 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
D50
Mean:
37.02 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
other: D75
Mean:
ca. 51.62 µm
Remarks on result:
other: The standard deviation was not provided.
Percentile:
D90
Mean:
66.25 µm
Remarks on result:
other: The standard deviation was not provided.

Applicant's summary and conclusion

Conclusions:
The particle size distribution of nickel oxalate powder was determined using a volumetric method. The particle diameters of D10%, D50% and D90% were 11.72, 37.02 and 66.25 µm, respectively.