Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove the casualty into fresh air and keep him calm.

When dust is intensively inhaled, seek medical help
immediately.
Emergency measure - Eyes: In case of contact with eyes rinse thoroughly with plenty of
water and seek medical advice.
Emergency measure - Skin: In case of contact with skin wash off immediately with soap
and water.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray jet or foam

Product arising from burning: Products of combustion may carbon monoxide, carbon dioxide,
sulfur oxides, hydrogen iodide and nitrogen oxides

Product determined by test: N

Protective equipment: Use self-contained breathing apparatus, wear full protective
suit.

Accidental release measures

Emergency measures in case of spillage: Pick up mechanically and send in suitable containers for
recovery or disposal.

Wear personal protective clothing. Use breathing apparatus
if exposed to vapours/dust/aerosols.

Do not allow to enter drains or waterways.

Handling and storage

Handling: Observe the usual precautions for handling chemicals, e.g.
wear chemical resistent gloves, safety glasses, protective
clothing, possibly for a short run filter apparatus with
filter A/P2.

Provide exhaust ventilation. Avoid inhalation of dust.

Storage: Keep only in original container. Keep container tightly
closed and dry in a cool, well-ventilated place. The storage
temperature should lie between 0 and 30 °C, maximum up to 50
°C.

Packaging of the substance and or preparation: PE-drum 150 l; 100 kg substance

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: RID, ADR Class 9, 12c, UN-No. 3077
Transport: Transport only in original containers
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: none known

Chemical reaction with water: slight acidic reaction

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: None

Industry - Possibility of neutralisation: The acidity can be neutralised adding sodium hydrogen
carbonate

Industry - Possibility of destruction: controlled discharge: None

Industry - Possibility of destruction - incineration: Controlled incineration with waste gas scrubber is possible

Industry - Possibility of destruction - water purification: At present not relevant

Industry - Possibility of destruction - other: None known

Public at large - Possibility of recovery/recycling: The substance does not enter the public domain.