Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The melting point was obtained by DSC (Differential Scanning Calorimetry) which is an accurate analysis method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report Date:
2006

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
DSC (Temp.Scan : 30 to 350°C at 3°C/min)
Gaz : Nitrogen
Stainless steel crucible
GLP compliance:
no
Type of method:
thermal analysis
Remarks:
Differential Scanning Calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
ca. 85 °C
Atm. press.:
ca. 760 mm Hg

Applicant's summary and conclusion

Conclusions:
Melting point is around 85°C at atmospheric pressure