Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was conducted according to standard guidelines (with GLP)
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Glycerides, C8-18 and C18-unsatd.
EC Number:
266-946-3
EC Name:
Glycerides, C8-18 and C18-unsatd.
Cas Number:
67701-28-4
IUPAC Name:
Glycerides, C8-18 and C18-unsatd.
Details on test material:
- Name of test material (as cited in study report): Fully hydrogenated coconut oil (CAS N° 84836-98-6, EC N° 284-283-8); under the SDA nomenclature, the name of this substance is ‘Glycerides, C8-18, C18 unsaturated’
- Physical state: Solid (bright yellow)
- Expiration date of the lot/batch: December 26, 2009
- Storage condition of test material: In original container, at room temperature (10-30 °C), in the dark

Results and discussion

Any other information on results incl. tables

The test item was spread on a non-combustible surface in the form of a rope 250 mm in length, with a cross section of ca. 1 cm2.

The rope was ignited with a flame of a gas burner. The flame was applied to the end of the rope for 2 minutes and the test item did not ignite. Therefore, it is not considered as highly flammable

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test material is not considered to be highly flammable.
Executive summary:

The test item was spread on a non-combustible surface in the form of a rope 250 mm in length, with a cross section of ca. 1 cm2.

The rope was ignited with a flame of a gas burner. The flame was applied to the end of the rope for 2 minutes and the test item did not ignite. Therefore, it is not considered as highly flammable and no further testing was conducted.