Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air, seek medical attention if
irritation develops.
Emergency measure - Eyes: Irrigate thoroughly with water for at least 15 minutes.
Obtain medical attention.
Emergency measure - Skin: Wash with water. Remove contaminated clothing.
Emergency measure - Ingestion: Seek immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Dry Powder, carbon dioxide, foam and water may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,
nitrogen and boron together with hydrogen fluoride and some
soot.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus and PVC protective
clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear appropriate protective clothing, see 2.3.1. Brush up,
take up using industrial vacuum. Place in suitable labelled
containers and dispose of by incineration

in accordance with local regulations.

Handling and storage

Handling: Observe the usual precautions for handling organic
chemicals. PVC gloves (type CE94,area of protection code
P713), an air hood (Plysu product code: FAA000014001100) and
disposal overalls (type CE95 0120, type 5 protection) should
be worn. Observe good industrial hygene practice to minimise
exposure.

Storage: Store in sealed polythene-lined UN approved fiberboard kegs
in a cool, dry, dark area.

Packaging of the substance and or preparation: 10 kg, 25 kg and 50 kg polythene-lined UN approved
fibreboard kegs.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: UN No. 1325, Class 4.1, Packing group III
Transport: HST No 293390 90
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: A test has been conducted: although the sample showed
energetic properties, it was not sufficiently hazardous to
be classified as explosive either for transport or supply.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling of the substance is not feasible. It
may be feasible to recycle the hydroxybenzotriazole part of
the molecule.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended, the substance should not be discharged to
landfill, sea or rivers.

Industry - Possibility of destruction - incineration: Incineration at a licensed facility with flue gas scrubbing
to remove oxides of nitrogen and hydrogen fluoride fumes.
(A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: Not applicable, the substance will not enter the public
domain.