First-aid measures

Emergency measure - Inhalation: If inhaled, remove to fresh air. If not breathing, give
artificial respiration. If breathing is difficult, give
oxygen. Call a physician.
Emergency measure - Eyes: In case of contact, immediately flush eyes with plenty of
water for at least 15 minutes. Call a physician.
Emergency measure - Skin: In case of contact, immediately wash skin with soap and
water. Wash contaminated clothing before reuse.
Emergency measure - Ingestion: Seek immediate chemical attention.

Fire-fighting measures

Recommended extinguishing agent: CO2, dry chemical powder or foam. Do not use water.

Product arising from burning: The substance is combustible and will burn if involved in a
fire, evolving noxious fumes (eg carbon and phosphorous
oxides).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.


Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards, as
mentioned in section 2.3.10.


Absorb spillages of solutions with a suitable inert material
(eg. sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original substance containers.


Clean the spillage area with detergent and water. Collect
the washings and dispose of as for waste material. Do not
direct washings to the drain.


Dispose of waste material in accordance with local
regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.


Engineering controls are necessary to reduce exposure to the
substance.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be
used, it must be capable of adequately controlling exposure,
be suitable for the purpose, and conform to the appropriate
international or national standards, such as a vapour
maskconforming to EN405 FFA1.

These measures should be regarded as a minimum.

Storage: Store in a cool, dry place.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: The preparation is shipped in a closed ISO tank to the use
site, where it is transferred to bulk storage.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: Provisionally classified as UN Class 3, Packing group II
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Chemical reaction with water: None which is hazardous.

Dust explosion: Not applicable to the marketed preparation.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration. It is possible to recover
larger spillages of uncontaminated material for subsequent
use.

Industry - Possibility of neutralisation: No chemical treatment is practicable to neutralise the
hazardous properties.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with
inert material (eg. sand or soil) should not be disposed of
by landfill.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg. carbon and
phosphorus oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Public at large - Possibility of recovery/recycling: Not applicable.