Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 483-310-2 | CAS number: 101023-55-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable solids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2008-04-24
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.10 (Flammability (Solids))
- Version / remarks:
- 1992
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- signed 2005-11-22
- Test procedure:
- burning rate test: preliminary screening test
- Burning time:
- 0 s
- Remarks on result:
- other: the test item could not be ignited
- Test procedure:
- ignition time on contact with air
- Result:
- 0 s
- Remarks on result:
- no ignition on contact with air (not further specified)
- Remarks on result:
- not measured/tested
- Remarks on result:
- not measured/tested
- Remarks on result:
- not measured/tested
- Interpretation of results:
- not classified based on GHS criteria
- Conclusions:
- The test item Imidazolhydrobromid could not be ignited. Therefore the test item is considered not to be highly flammable.
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
Testing for flammability in contact with water is not considered to be required, because the substance does not contain groups that might lead to a reaction with water or damp air, leading to the development of dangerous amounts of gas or gases which may be highly flammable. Furthermore, long-term industrial experience in practical handling of the substance shows that it does not react with water, and recent experimental testing for water solubility has also not reported any formation of gases (in accordance with section 1, Annex XI of Regulation (EC) 1907/2006). - Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
Testing for pyrophoric properties of solids is not considered to be required, since this substance is stable at ambient temperature. This substance also does not contain any chemical groups that might lead to spontaneous ignition a short time after coming in contact with air at room temperature (circa 20 °C) . Furthermore, long-term industrial experience in handling shows that the substance does not ignite in contact with air (in accordance with section 1, Annex XI of Regulation (EC) 1907/2006).
Referenceopen allclose all
Preliminary test:
The test item did not ignite.
Main test:
As the test item could not be ignited in the preliminary test it should not be considered as highly flammable and no further testing was required. Therefore no main test was performed.
Description of key information
Flammability solid: The test item Imidazolhydrobromid could not be ignited. Therefore the test item is considered not to be highly flammable.
Pyrophoric properties: Imidazolhydrobromid does not ignite in contact with air.
Flammability in contact with water: Imidazolhydrobromid does not ignite in contact with water.
Key value for chemical safety assessment
- Flammability:
- non flammable
Additional information
Pyrophoric properties
Testing for pyrophoric properties of solids is not considered to be required, since this substance is stable at ambient temperature. This substance also does not contain any chemical groups that might lead to spontaneous ignition a short time after coming in contact with air at room temperature (circa 20 °C) . Furthermore, long-term industrial experience in handling shows that the substance does not ignite in contact with air (in accordance with section 1, Annex XI of Regulation (EC) 1907/2006).
Flammability in contact with water
Testing for flammability in contact with water is not considered to be required, because the substance does not contain groups that might lead to a reaction with water or damp air, leading to the development of dangerous amounts of gas or gases which may be highly flammable. Furthermore, long-term industrial experience in practical handling of the substance shows that it does not react with water, and recent experimental testing for water solubility has also not reported any formation of gases (in accordance with section 1, Annex XI of Regulation (EC) 1907/2006).
Justification for classification or non-classification
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.