Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-03-30 to 2021-11-07
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: EC Guideline A.24. Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
Version / remarks:
1996
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
4-chloro-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Cas Number:
2270944-70-0
Molecular formula:
C15H16ClN5O4
IUPAC Name:
4-chloro-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch (Lot) Number: I20CD1048
- Purity/Composition: 100%
- Purity test date : 2020-05-11
- Expiry date: 2022-03-22 (retest date)
- Physical Description: Light yellow to dark orange solid

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature
- Stability and homogeneity of the test material in the vehicle/solvent under test conditions and during storage: not indicated
- Stability in the medium, i.e. sensitivity of the test material to hydrolysis and/or photolysis: not indicated
- Solubility and stability of the test material in the solvent/vehicle and the exposure medium: not indicated
- Reactivity of the test material with the incubation material used (e.g. plastic ware): not indicated

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
No treatment

OTHER SPECIFICS
- Purity/Composition correction factor: Yes, correction factor is 1.0

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficientopen allclose all
Key result
Type:
log Pow
Partition coefficient:
3.2
Temp.:
35 °C
pH:
7
Remarks on result:
other: Column temperature: 35°C +/- 1°C
Key result
Type:
log Pow
Partition coefficient:
3.3
Temp.:
35 °C
pH:
7
Remarks on result:
other: Column temperature 35°C +/- 1°C
Details on results:
Pow Calculation
The Pow of the test item was calculated to be 2.0 x 10^2 (log Pow 2.3) using the Rekker
calculation method.

pKa Values
No pKa values for acidic groups in the molecular structure of the test item in the logarithm
range of 1 - 14 were calculated.
The pKa values in the logarithm range of 1 - 14 for basic groups in the molecular structure of
the test item were calculated using the Perrin calculation method

HPLC Method

The results of the HPLC method are given in the Table 9. The calibration
curve of the log k’ of the reference substances as function of log Pow was calculated. The equation of the regression line was: log k’ = 0.336 x log Pow – 0.810 (r = 0.995, n = 18).

Any other information on results incl. tables

pKa Values of the test item












Basic

RARN(R1R2)


Pyrimidinium


RARN(R1R2)



pKa 3.2


pKa 2.1


pKa 1.1



Pow of the Test Item




































Substance


 



 Retention time min


 


 



 


log Pow



 


Pow



 


Mean


peak area (%)



tr,1



tr,2



mean



Formamide (to)


Benzylalcohol


Nitrobenzene


Toluene


I ,4-Dichlorobenzene


Biphenyl


I ,4-Trichlorobenzene


Dibenzyl


Triphenylamine


44' -DDT



0.794


0.983


1.572


2.054


2.772


3.197


4.616


8.499


12.532



0.609


0.798


0.986


1.576


2.056


2.773


3.201


4.660


8.650


12.793



0.612


0.796


0.985


1.574


2.055


2.773


3.199


4.638


8.575


12.663



 


1.1


1.9


2.7


3.4


4.0


4.2


4.8


5.7


6.5



 


 


 


 


 


 


 


 


 


 



 



Test item — peak I


Test item — peak 2



1.699


1.808



1.694


1.802



1.697


1.805



3.2


3.3



1.4 x 103


1.9 x 103



98


1.6


Applicant's summary and conclusion

Conclusions:
The HPLC method at neutral pH was applied for the determination of the partition coefficient
(Pow) of JNJ-73848242-AAA (T003901).
The Pow and log Pow values of the test item at neutral pH were:
Test item – peak 1: Pow1.4 x 10E+3; log Pow 3.2; mean peak area 98%
Test item – peak 2: Pow1.9 x 10E+3; log Pow 3.3; mean peak area 1.6%