Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-17 to 2021-06-25
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-chloro-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Cas Number:
2270944-70-0
Molecular formula:
C15H16ClN5O4
IUPAC Name:
4-chloro-N-[2-methoxy-4-(morpholin-4-yl)-5-nitrophenyl]pyrimidin-2-amine
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch (Lot) Number: I20CD1048
- Purity/Composition: 100%
- Purity test date : 2020-05-11
- Expiry date: 2022-03-22 (retest date)
- Physical Description: Light yellow to dark orange solid

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature
- Stability and homogeneity of the test material in the vehicle/solvent under test conditions and during storage: not indicated
- Stability in the medium, i.e. sensitivity of the test material to hydrolysis and/or photolysis: not indicated
- Solubility and stability of the test material in the solvent/vehicle and the exposure medium: not indicated
- Reactivity of the test material with the incubation material used (e.g. plastic ware): not indicated

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
No treatment

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Remarks:
The test item of JNJ-73848242-AAA (T003901) was observed to exhibit no reaction at 40 J.
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Remarks:
The test item of JNJ-73848242-AAA (T003901) was observed to exhibit no reaction at 360 N.
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
thermal sensitive if heated under defined confinement
Remarks:
The test item did not exhibit an explosion during any of the tests.

Any other information on results incl. tables


  1. BAM FALLHAMMER: Test Procedure



The test item was placed in the impact device and the 10 kg weight dropped from a height of 40 cm which is equivalent to 40 J. If an "explosion" was observed, the impact energy was reduced to 7.5 J and further tests conducted.


Table 8:1: Test Results



















Mass (kg)Height (m)Energy (J)Test number and result* (X / ✓)Comments
10 0.4 40 

1 2 3 4 5 6


X X X X X X 


No reaction


* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).

2. BAM FRICTION: Test procedure


Table 9:1: Test Results

















Mass (kg)Load (N)Test number and result* (X / ✓)Comments
10 360

1 2 3 4 5 6


X X X X X X 


No reaction


* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).


3. KOENEN TUBE: Test procedure


Table 10:1 : Full test results















































Mass of test item (g)Orifice Diameter (mm)Time for First Ignition (s)Explosion (X / ✓)*
16.3614X
16.3615X
16.3615X
16.3210X
16.3211X
16.3211X

* ‘✓’ denotes 3 or more fragments.
‘X’ denotes fewer than 3 fragments.


 

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
BAM FALLHAMMER Test: The test item of JNJ-73848242-AAA (T003901) was observed to exhibit no reaction at 40 J. The test result is therefore considered Negative (-) (according to the EC
Classification, Packaging & Labelling of Dangerous Substances in the European Union
Part 2, Testing Methods, Jan 97).

BAM FRICTION Test: The test item of JNJ-73848242-AAA (T003901) was observed to exhibit no reaction at 360 N. The test result is therefore considered Negative (-) (according to the EC
Classification, Packaging & Labelling of Dangerous Substances in the European Union
Part 2, Testing Methods, Jan 97).

KOENEN TUBE Test: The test item did not exhibit an explosion during any of the tests. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging &
Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan 97).