Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental start date 28th April 2021. Experimental completion date 28th April 2021.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EU Method A.24 (Partition Coefficient (n-Octanol/Water), High Performance Liquid Chromatography (HPLC) Method)
Version / remarks:
2015
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Name: BHET
Batch no.: AWS0274J
Purity: ~95%
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
< 1.6
Temp.:
25 °C
Remarks on result:
other: Test item is assumed to consist of 2 peaks. The highest log Pow for peak 2 is reported here.
Details on results:
It is assumed that the test item consist of two peaks.

The first peak eluted with a retention time slightly before the reference item with the lowest log Pow (log Pow 0.3). The log Pow was extrapolated to -0.114 ± 0.0. A calculated value by EPISuite gives a log Pow of 0.12. Since both the extrapolated value and the values obtained by EPISuite are < 0.3, the log Pow for this first peak is stated as < 0.3.

The second peak eluted within the calibration range with a log Pow of 1.587.

The log Pow for the test item is reported as < 0.3 to 1.6.
Conclusions:
The log Pow of the test item is stated as < 0.3 - 1.6.
Executive summary:

The log Pow was assessed following the HPLC method according to GLP.  The test item is assumed to elute with 2 peaks.


Peak 1: log Pow was outside of the calibration range and is reported as < 0.3


Peak 2: log Pow was within the calibration range and is reported as 1.6


 


The log Pow for the test item is between < 0.3 and 1.6.

Description of key information

The test item is assumed to elute with two peaks. The log Pow for the test item is between < 0.3 and 1.6. The log Pow used for the Risk Assessment is the maximum value of 1.6.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.6
at the temperature of:
25 °C

Additional information