Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 Apr 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material:
41-4205-7138-6 (R-57318), CPDC Load ID S352546
- Purity: 99.7%
- Expiration date: 01 May 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Stored at room temperature
Key result
Flash point:
86.3 °C
Atm. press.:
101.4 kPa
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
MTDID 44428 has a flash point of 86.3 °C at 101.4 kPa (EC A.9).
Executive summary:

The flash point of MTDID 44428 was tested using a Pensky-Martens closed-cup apparatus. Starting at 47 °C, the test material was heated 5 to 6 °C/min and an attempt was made to ignite  the test substance every 1 °C temperature rise. Flash point was observed at 86.3 °C. The study was conducted in accordance with EU method A.9 (Flash-Point) and was GLP compliant. Therefore, the study is considered reliable without restrictions.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion