Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
effusion method: isothermal thermogravimetry
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material:
Jiu Jiang Tinci Materials Technology Co., Ltd.
G200810043
- Purity, including information on contaminants, isomers, etc.:

>99.8%


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
In the refrigerator (2~8 °C), easy to hydrolyze and not in contact with moisture
- Stability and homogeneity of the test material in the vehicle/solvent under test conditions (e.g. in the exposure medium) and during storage:
Stable
- Stability in the medium, i.e. sensitivity of the test material to hydrolysis and/or photolysis:
Stable
- Solubility and stability of the test material in the solvent/vehicle and the exposure medium:
The test substance is soluble in water.
- Reactivity of the test material with the incubation material used (e.g. plastic ware):

Non reactive

Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.003 Pa
Conclusions:
At the temperature of 20.0 °C, the vapour pressure PT of test item was 2.87E-03 Pa.

Description of key information

At the temperature of 20.0 °C, the vapour pressure PTof test item was 2.87E-03 Pa.

Key value for chemical safety assessment

Vapour pressure:
0.003 Pa
at the temperature of:
20 °C

Additional information