Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because the substance is marketed or used in a non solid or granular form
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with REACH Regulation (EC) No. 1907/2006 Annex VII, column 2 section 7.14 the study does not need to be conducted if the substance is marketed or used in a non-solid or granular form. The substance is a liquid. According to ECHA Guidance on Information Requirements and Chemical Safety Assessment (Chapter R.7a: Endpoint Specific Guidance, R.7.1.14, July 2017) the study does not need to be conducted.
Cross-reference
Reason / purpose for cross-reference:
reference to other study
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16-10-2017 to 11-05-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Visual observation of physical state and appearance by the testing laboratory
Qualifier:
no guideline required
Principles of method if other than guideline:
Visual observation of physical state and appearance by the testing laboratory
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected: July 2016 ; signature: October 2016
Physical state at 20°C and 1013 hPa:
liquid
Form:
liquid
Colour:
Slightly yellow
Substance type:
organic
Conclusions:
The physical state and appearance of the test item were evaluated by visual observation. The test item was determined to be a slightly yellow liquid.
Executive summary:

The appearance of the test item has been determined as:

Form: liquid

Colour: slightly yellow

Data source

Materials and methods

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.

Applicant's summary and conclusion