Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 28 January 2019 Experimental completion date: 31 January 2019
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3-sec-[C15-18-(branched and linear)-alk-2-enyl]pyrrolidine-2,5-dione
EC Number:
701-350-3
Molecular formula:
Not possible to assign, UVCB
IUPAC Name:
3-sec-[C15-18-(branched and linear)-alk-2-enyl]pyrrolidine-2,5-dione
Test material form:
liquid
Details on test material:
- Appearance: brown liquid
- Storage: room temperature, in the dark
Specific details on test material used for the study:
Identification: X-16151
Appearance/Physical state:Dark brown viscous liquid
Batch:R18 13101
Purity:UVCB 100%
Expiry date:02 August 2020
Storage conditions:Room temperature in the dark

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
372 °C
Atm. press.:
>= 99.2 - <= 100.5 kPa

Any other information on results incl. tables

Results

Results of the auto-ignition temperature determination are shown in the following table:

Temperature (ºC)

Clean Flask (Yes/No)

Volume (µL)

Ignition Delay (s)

Observations

200

Yes

70

>300

No ignition. Grey fumes were emitted.

250

Yes

70

>300

No ignition. Grey fumes were emitted.

300

Yes

70

>300

No ignition. Grey fumes were emitted.

350

No

70

>300

No ignition. Grey fumes were emitted.

400

No

70

4

An orange flame. Grey fumes were emitted.

380

Yes

70

>300

No ignition. Grey fumes were emitted.

390

Yes

70

5

An orange flame. Grey fumes were emitted.

 

Temperature (ºC)

Clean Flask (Yes/No)

Volume (µL)

Ignition Delay (s)

Observations

386

No

70

>300

No ignition. Grey fumes were emitted.

388

No

70

8

A blue/orange flame. Grey fumes were emitted.

386

Yes

70

>300

No ignition. Grey fumes were emitted.

386

Yes

200

6

An orange flame. Grey fumes were emitted.

384

Yes

200

5

An orange flame. Grey fumes were emitted.

382

Yes

200

6

An orange flame. Grey fumes were emitted.

380

Yes

200

>300

No ignition. Grey fumes were emitted.

380

Yes

400

12

An orange flame. Grey fumes were emitted.

378

Yes

400

>300

No ignition. Grey fumes were emitted.

378

Yes

600

>300

No ignition. Grey fumes were emitted.

378

Yes

800

9

A blue/orange flame. Grey fumes were emitted.

376

Yes

800

11

A blue/orange flame. Grey fumes were emitted.

374

Yes

800

>300

No ignition. Grey fumes were emitted.

374

Yes

1000

>300

No ignition. Grey fumes were emitted.

374

Yes

600

>300

No ignition. Grey fumes were emitted.

374

Yes

400

8

A blue/orange flame. Grey fumes were emitted.

372

Yes

400

10

A blue/orange flame. Grey fumes were emitted.

370

Yes

400

>300

No ignition. Grey fumes were emitted.

370

Yes

600

>300

No ignition. Grey fumes were emitted.

370

Yes

800

>300

No ignition. Grey fumes were emitted.

370

Yes

1000

>300

No ignition. Grey fumes were emitted.

370

Yes

200

>300

No ignition. Grey fumes were emitted.

Room temperature:16 to 17°C
Atmospheric pressure:
99.2 to 100.5kPa

Applicant's summary and conclusion

Conclusions:
The test item has been determined to have an auto-ignition temperature of 372 °C.
Executive summary:

The determination was carried out using a procedure*designed to be compatible with Method A.15 Auto-IgnitionTemperature (Liquids and Gases) of Commission Regulation (EC) No 440/2008 of 30 May 2008.


*Based on, Anon (2010), Explosive atmospheres – Part 20-1: Material characteristics for gas and vapour classification – test methods and data, Method of test for auto-ignition temperature. IEC 60079-20-1:2010
P1-77.

Conclusion

The test item has been determined to have an auto-ignition temperature of 372 °C.