Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24.04.2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Sample is a Pyrolysis oil from waste rubbers and tires manufactured by Reoil Sp. z o.o.
Batch number: PO_200423_K3
Sample collection: 23/04/2020
Key result
Flash point:
22 °C
Atm. press.:
1 013 hPa
Interpretation of results:
Category 2 (highly flammable liquids) based on GHS criteria
Conclusions:
Due to flash point < 23°C and initial boiling point > 35°C, the substance is classified as H225: Highly flammable liquid and vapour.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
22 °C

Additional information