Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report Date:
1992

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Type of method:
effusion method: Knudsen cell

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.04 Pa
Test no.:
#2
Temp.:
50 °C
Vapour pressure:
1 Pa
Test no.:
#3
Temp.:
100 °C
Vapour pressure:
90 Pa

Applicant's summary and conclusion