Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 June 2016 to 21 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Deviations:
yes
Remarks:
he incubation time after the test item removal was 16 min too short. Evaluation: Since the positive and negative control met the acceptance criteria, this does not affect the study results.
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-chloro-6-ethenyl-5-fluoropyrimidine
EC Number:
940-222-3
Cas Number:
1403893-61-7
Molecular formula:
C6 H4 Cl F N2
IUPAC Name:
4-chloro-6-ethenyl-5-fluoropyrimidine
Test material form:
liquid
Details on test material:
received as orange brown liquid
Specific details on test material used for the study:
Batch K47177483 Purity >= 99.9% Storage conditions At room temperature
Stable under storage conditions until 31 October 2020

Test animals / tissue source

Species:
cattle
Strain:
not specified
Details on test animals or tissues and environmental conditions:
Test System: Bovine eyes were used as soon as possible after slaughter.
Rationale: In the interest of sound science and animal welfare, a sequential testing strategy is recommended to minimise the need of in vivo testing (1-6). As a consequence a validated and accepted in vitro test for eye irritation should be performed before in vivo tests are conducted. One of the proposed validated in vitro eye irritation tests is the Bovine Corneal Opacity and Permeability (BCOP) test.
Source: Bovine eyes from young cattle were obtained from the slaughterhouse (Vitelco, 's Hertogenbosch, The Netherlands), where the eyes were excised by a slaughterhouse employee as soon as possible after slaughter.
Transport: Eyes were collected and transported in physiological saline in a suitable container under cooled conditions.

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
The test item was applied as it is (750 µl) directly on top of the corneas.
Duration of treatment / exposure:
10 minutes
Duration of post- treatment incubation (in vitro):
10 minutes
Number of animals or in vitro replicates:
3
Details on study design:
Preparation of corneas
The eyes were checked for unacceptable defects, such as opacity, scratches, pigmentation and neovascularization by removing them from the physiological saline and holding them in the light. Those exhibiting defects were discarded.
The isolated corneas were stored in a petri dish with cMEM (Earle’s Minimum Essential Medium (Life Technologies, Bleiswijk, The Netherlands) containing 1% (v/v) L-glutamine (Life Technologies) and 1% (v/v) Foetal Bovine Serum (Life Technologies)). The isolated corneas were mounted in a corneal holder (one cornea per holder) of BASF (Ludwigshafen, Germany) with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was positioned on top of the cornea and tightened with screws. The compartments of the corneal holder were filled with cMEM of 32 ± 1°C. The corneas were incubated for the minimum of 1 hour at 32 ± 1°C.

Cornea selection and Opacity reading
After the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer (BASF-OP3.0, BASF, Ludwigshafen, Germany). The opacity of each cornea was read against a cMEM filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 7 were not used. Three corneas were selected at random for each treatment group.

Treatment of corneas and opacity measurements
The medium from the anterior compartment was removed and 750 µl of either the negative control, positive control (Ethanol) or test item was introduced onto the epithelium of the cornea. The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the control or the test item over the entire cornea. Corneas were incubated in a horizontal position for 10 ± 1 minutes at 32 ± 1°C. After the incubation the solutions were removed and the epithelium was washed with MEM with phenol red (Earle’s Minimum Essential Medium, Life Technologies) and thereafter with cMEM. Possible pH effects of the test item on the corneas were recorded. The medium in the posterior compartment was removed and both compartments were refilled with fresh cMEM. Subsequently the corneas were incubated for 120 ± 10 minutes at 32 ± 1°C. After the completion of the incubation period opacity determination was performed. Each cornea was inspected visually for dissimilar opacity patterns.

Opacity measurement
The opacity of a cornea was measured by the diminution of light passing through the cornea. The light was measured as illuminance (I = luminous flux per area, unit: lux) by a light meter.
The change in opacity for each individual cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final post-treatment reading. The corrected opacity for each treated cornea with the test item or positive control was calculated by subtracting the average change in opacity of the negative control corneas from the change in opacity of each test item or positive control treated cornea.
The mean opacity value of each treatment group was calculated by averaging the corrected opacity values of the treated corneas for each treatment group.

Application of sodium fluorescein
Following the final opacity measurement, permeability of the cornea to Na-fluorescein (Sigma-Aldrich, Germany) was evaluated.
The medium of both compartments (anterior compartment first) was removed. The posterior compartment was refilled with fresh cMEM. The anterior compartment was filled with 1 ml of 4 mg Na-fluorescein (Sigma-Aldrich Chemie GmbH, Germany)/ml cMEM solution. The holders were slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the sodium-fluorescein solution over the entire cornea. Corneas were incubated in a horizontal position for 90 ± 5 minutes at 32 ± 1°C.

Permeability determinations
After the incubation period, the medium in the posterior compartment of each holder was removed and placed into a sampling tube labelled according to holder number. 360 µl of the medium from each sampling tube was transferred to a 96-well plate. The optical density at 490 nm (OD490) of each sampling tube was measured in triplicate using a microplate reader (TECAN Infinite® M200 Pro Plate Reader). Any OD490 that was 1.500 or higher was diluted to bring the OD490 into the acceptable range (linearity up to OD490 of 1.500 was verified before the start of the experiment). OD490 values of less than 1.500 were used in the permeability calculation.
The mean OD490 for each treatment was calculated using cMEM corrected OD490 values. If a dilution has been performed, the OD490 of each reading of the positive control and the test item was corrected for the mean negative control OD490 before the dilution factor was applied to the reading.

In vitro irritancy score
The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:
In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value)
Additionally the opacity and permeability values were evaluated independently to determine whether the test item induced irritation through only one of the two endpoints.
The IVIS cut-off values for identifying the test items as inducing serious eye damage (UN GHS Category 1) and test items not requiring classification for eye irritation or serious eye damage (UN GHS No Category) are given hereafter:
In vitro score range UN GHS
< 3 No Category
> 3; < 55 No prediction can be made
>55 Category 1

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
in vitro irritation score
Run / experiment:
test item
Value:
ca. 34
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
not determinable
Irritation parameter:
in vitro irritation score
Run / experiment:
positive control
Value:
ca. 57
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
positive indication of irritation
Other effects / acceptance of results:
The assay is considered acceptable if:
• The positive control gives an in vitro irritancy score that falls within two standard deviations of the current historical mean.
• The negative control responses should result in opacity and permeability values that are less than the upper limits of the laboratory historical range.

Applicant's summary and conclusion

Interpretation of results:
study cannot be used for classification
Conclusions:
Since PF-06645243 induced an IVIS > 3 ≤ 55 no prediction on the classification can be made.
Executive summary:

Evaluation of the eye hazard potential of  PF-06645243 using the Bovine Corneal Opacity and Permeability test (BCOP test).

This report describes the potency of chemicals to induce serious eye damage using isolated bovine corneas. The eye damage of  PF-06645243 was tested through topical application for 10 minutes.

The study procedures described in this report were based on the most recent OECD guideline.

Batch 2000533255 of  PF-06645243 was a light yellow oil with a purity of 99.2%. The test item was applied as it is (750 µl) directly on top of the corneas.

The negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas. The mean in vitro irritancy score of the positive control (Ethanol) was 57 and was within two standard deviations of the current historical positive control mean. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.

PF-06645243 induced ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of 34 after 10 minutes of treatment.

Since  PF-06645243 induced an IVIS > 3 ≤ 55 no prediction on the classification can be made.