Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2015
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM B923-10 Standard Test Method for Metal Powder Skeletal Density by Helium or Nitrogen Pycnometer – Committee B09 on Metal Powder and Metal Powder Products
GLP compliance:
not specified
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction Mass of Dialuminium Titanium Pentoxide and Strontium Calcium Aluminosilicate
Molecular formula:
71-75%(Al2TiO5) 22-24%(Sr0.8Ca0.2Al2Si2O8) 2-5%(Al2O3) 0-2(TiO2)
IUPAC Name:
Reaction Mass of Dialuminium Titanium Pentoxide and Strontium Calcium Aluminosilicate
Test material form:
solid

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 2.4 g/cm³
Temp.:
20 °C

Applicant's summary and conclusion