Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 May 2018 - 03 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD 113 Screening test for thermal stability and stability in air
Deviations:
no
GLP compliance:
no
Key result
Parameter:
other: decomposition energy in J/g
Value:
474

The main test on explosive properties was not necessary because the heat of decomposition was below 500 J/g as determined by using a differential scanning calorimetry.

Interpretation of results:
GHS criteria not met
Conclusions:
The test item had no explosive properties in the sense of the European Commission Regulation (EC) No 440/2008, Method A.14.

Description of key information

The test item had no explosive properties in the sense of the European Commission Regulation (EC) No 440/2008, Method A.14.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The test item is not considered to be explosive according to Regulation (EC) 1272/2008.