Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 641-894-8 | CAS number: 6740-87-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 24 August - 16 November 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- other: ISO 13320-1
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: CIPAC MT 187
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: CTL SOP No. 417
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- Laser scattering/diffraction
- Type of distribution:
- volumetric distribution
Test material
- Reference substance name:
- 1-[(2-chlorophenyl)(methylimino)methyl]cyclopentan-1-ol
- EC Number:
- 641-894-8
- Cas Number:
- 6740-87-0
- Molecular formula:
- C13H16ClNO
- IUPAC Name:
- 1-[(2-chlorophenyl)(methylimino)methyl]cyclopentan-1-ol
- Test material form:
- solid
Constituent 1
- Specific details on test material used for the study:
- - Lot/batch No.of test material: I17BB0589
- Expiration date of the lot/batch: 12 February 2018 (retest date)
- Analytical Purity: 99.50% (based on chromatographic purity)
- Storage condition of test material: In refrigerator (2-8°C) under argon
Results and discussion
- Mass median aerodynamic diameter:
- 454.026 µm
- Geometric standard deviation:
- >= 2.24 - <= 2.37
Particle sizeopen allclose all
- Percentile:
- D10
- Mean:
- 115.053 µm
- St. dev.:
- 2.672
- Remarks on result:
- other: Average result is calculated from the entirety of data captured in each run and is not a simple arithmetic mean.
- Key result
- Percentile:
- D50
- Mean:
- 402.883 µm
- St. dev.:
- 4.997
- Remarks on result:
- other: Average result is calculated from the entirety of data captured in each run and is not a simple arithmetic mean.
- Percentile:
- D90
- Mean:
- 762.875 µm
- St. dev.:
- 10.705
- Remarks on result:
- other: Average result is calculated from the entirety of data captured in each run and is not a simple arithmetic mean.
Any other information on results incl. tables
Visual Microscope Analysis
(1) Standard visual observation: sample observed to be a medium and coarse white powder.
(2) 3.2 objective lens: particles appeared to be irregular shaped crystals (smallest +/- 19 µm and largest +/- 960 µm).
(3) 40 objective lens: sample was observed to be made up of single crystalline particles.
Laser Diffraction Particle Size Analysis
Using the identified parameters, the particle size was analysed over the range 0.2 μm to 2000 μm.
The average Volume weighted Mean was 426.456µm and the mode was 488.994µm. The Coefficient of Variation for d50 was <3%; d10 and d90 were <5%. Thus the repeatability of the characteristic particles in the size distribution was within the acceptable limits according to the ISO 13320-1 test standard.
Applicant's summary and conclusion
- Conclusions:
- Visual examination using 3.2 objective lens showed irregular shaped crystals between approximately 19 µm and 960 µm.
The particle size distribution of T003641 determined by the laser diffraction method led to the conclusion that the average volume weighted mean based on 5 runs was 426.456 µm and the Mass Median Aerodynamic Diameter (MMAD) based on 5 runs was 454.026 µm, whereas the average D10, D50 and the D90 were determined to be 2.672 µm, 4.997 µm and 10.705 µm, respectively.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.