Administrative data

Endpoint:
skin irritation / corrosion, other
Remarks:
In vitro EPIDERM™ Skin Corrosion Test
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
Version / remarks:
Method B.40bis of Commission Regulation (EC) No 440/2008, of 30 May 2008, laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Salt of N-acetyl-L-glutamic acid and 1-[(7S)-3,4-dimethoxybicyclo[4.2.0]octa-1,3,5-trien-7-yl]methanamine (1:1), monohydrate
EC Number:
922-576-0
Cas Number:
1184182-45-3
Molecular formula:
C18H28N2O8
IUPAC Name:
Salt of N-acetyl-L-glutamic acid and 1-[(7S)-3,4-dimethoxybicyclo[4.2.0]octa-1,3,5-trien-7-yl]methanamine (1:1), monohydrate
Test material form:
solid: particulate/powder

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Run 1 (duration of exposure: 3 minutes
Run 1, replicate 1 (duration of exposure: 3 minutes)
Run 2 (duration of exposure: 1 hour
Run 2, replicate 1 (duration of exposure: 1 hour)
Value:
>= 102 - <= 106.7
Vehicle controls validity:
not valid
Negative controls validity:
valid
Positive controls validity:
valid

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was considered to be non-corrosive to the skin.