Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-03-03 to 2017-03-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
EC Number:
309-627-7
EC Name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
Cas Number:
100545-46-8
Molecular formula:
C32H16-τN8Cu.(SO3)m.(SO3H)p.(C9H19N2SO2)O.(C9H20N2SO2)n
IUPAC Name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: In darkness at room temperature


Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Assay No. 1

The test item ignited at the contact of the flame’s burner and became purple, red and

hard. No propagation of the combustion was observed.

Assay No. 2

The same observations as for the assay No. 1 were recorded

Main test

Taking into account the results obtained during the preliminary test, no main test was performed.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Conclusion
The test item was not classified as a flammable solid of Division 4.1 and thus was not assigned to any packing group, under the experimental conditions used.
According to EC No. 1272/2008 (CLP), the test item was not classified.
Executive summary:

Conclusion

The test item was not classified as a flammable solid of Division 4.1 and thus was not assigned to any packing group, under the experimental conditions used.

According to EC No. 1272/2008 (CLP), the test item was not classified.