Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15.05.1995 - 13.09.1995
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Value:
39.24
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Value:
353.16
Remarks on result:
not sensitive to friction using a friction load of 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Interpretation of results:
GHS criteria not met
Conclusions:
The test material has been determined not to have explosive properties.
Executive summary:

The experimental procedure used complied with that specified in Method A14 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

Description of key information

The test material has been determined not to have explosive properties.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification