Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Oct 2017 - Feb 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Essential oil of Gurjun obtained from the resin tapped from Dipterocarpus trees (Dipterocarpaceae) by steam distillation (Gurjunene quality)
EC Number:
947-839-7
IUPAC Name:
Essential oil of Gurjun obtained from the resin tapped from Dipterocarpus trees (Dipterocarpaceae) by steam distillation (Gurjunene quality)
Test material form:
liquid
Details on test material:
Name in used in report: Gurrjun Balsam oil (Gurjunene)
Test facility number 209144/A


SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: obtained from sponsor, Batch no. 2642704.
- Expiration date of the lot/batch: 28-02-2018 and extended to 28-12-2018 (30-03-2018)
- Purity test date: 20-09-2017


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room tempersture.

OTHER SPECIFICS: UVCB

Specific details on test material used for the study:
Name in used in report: Gurrjun Balsam oil (Gurjunene)
Test facility number 209144/A


SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: obtained from sponsor, Batch no. 2642704.
- Expiration date of the lot/batch: 28-02-2018 and extended to 28-12-2018 (30-03-2018)
- Purity test date: 20-09-2017


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room tempersture.

OTHER SPECIFICS: UVCB

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
225 °C
Atm. press.:
> 987 - < 1 009 hPa

Applicant's summary and conclusion

Conclusions:
The auto-ignition temperature of Gurjun balsam oil (Gurjunene) is 225°C at 987-1009 hPa.
Executive summary:

The test item Gurjun balsam oil (Gurjunene) has an auto-ignition temperature of 225 °C at 987 - 1009 hPa according to the guidelines: EU A.15 / DIN 51749 / IEC 60079-4.