Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 December 2017 to 01 June 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
Calcium Isooctadecanoate was observed to burn at point of contact with the burner flame and then turn to ash. The burner flame was applied for 2 minutes and the flames extinguished upon removal of the burner. The flame did not propagate along the train
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item was found to not highly flammable in the preliminary test.The test item was observed to burn at point of contact with the burner flame and then turn to ash. The burner flame was applied for 2 minutes and the flames extinguished upon removal of the burner. The flame did not propagate along the train.
Executive summary:

The flammability of the test item was investigated in an EC Method A.10 study. In the preliminary test, the test item was found to be not highly flammable and, therefore, a definitive test was not required.

The study is a GLP-compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The test item is concluded to be not highly flammable (not classified based on GHS criteria) based on a preliminary test. The test item was observed to burn at point of contact with the burner flame and then turn to ash. The burner flame was applied for 2 minutes and the flames extinguished upon removal of the burner. The flame did not propagate along the train.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test item was investigated in a GLP-compliant EC Method A.10 study that is fully acceptable for assessment of this endpoint (Dunning 2018).

Justification for classification or non-classification

The test item is concluded to be not highly flammable (not classified based on GHS criteria) based on a preliminary test. The test item was observed to burn at point of contact with the burner flame and then turn to ash. The burner flame was applied for 2 minutes and the flames extinguished upon removal of the burner. The flame did not propagate along the train.