Administrative data

First-aid measures

Inhalation:

After inhalation move to fresh air. If shortness of breath occurs, support respiration and consult a physician.

Skin Contact

Remove contaminated clothing. Rinse contaminated skin immediately with plenty of water and soap and seek medical advice.

Eye Contact

Immediately rinse eyes thoroughly with running water as long as possible (approx. 15 min). Take injured quickly to factory medical center or call an ambulance (code word: eye accident).

Ingestion

Do not induce vomiting. In case of consciousness wash mouth with water and let drink some of water. Seek medical advice. Keep patient at rest.

Fire-fighting measures

1 Extinguishing media

Suitable Extinguishing Media

Water spray or fog, foam, dry chemical powder, CO2, dry sand

Unsuitable Extinguishing Media

No restrictions

2 Special hazards arising from the substance or mixture

Dangerous Combustion Products

carbon oxides

nitrogen oxides

3 Advice for firefighters

Protective equipment for firefighters

Wear self-contained breathing apparatus and fire protective suite.

Accidental release measures

1 Personal precautions, protective equipment and emergency procedures

Personal precautions

Avoid contact with skin, eyes and clothing.

2 Environmental precautions

Environmental precautions

Must not be released into sewers, drains or wells.

3 Methods and material for containment and cleaning up

Methods for cleaning Transfer large quantities into a container, rinse the rest with plenty of water.

Handling and storage

1 Precautions for safe handling

Storage and Handling Precautions

Open handling without suitable personal protective equipment must be avoided. Keep container tightly closed in a dry, cool and well-ventilated place. Ensure efficient exhaust ventilation when using this product

2 Conditions for safe storage, including any incompatibilities

Conditions of storage

Protect against humidity

Technical measures/ Precautions

Handle product only in closed system or provide appropriate exhaust ventilation at machinery.

Preventive Precautions

(fire/explosion)

Take precautionary measures against static discharges. Avoid formation of dust. Keep away from sources of ignition. Observe the usual precautionary measures required for chemicals with dust explosive properties (Observe national regulations).

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
0
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
0
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
0
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Industrial Hygiene

The personal protective measure may be adapted appropriately when working in closed systems or under laboratory conditions.

Regular cleaning of equipment, work area and clothing.

No open handling without using reliable equipment. One technical barrier between substance and employee resp. environment.

Restricted and controlled access for trained personnel only.

Designated washing, changing and shower facilities must be available.

Internal working procedures available to personnel covering personal hygiene, decontamination /cleaning, consideration of worst case incidents, spills, emergency, alarms, waste disposal and maintenance.

Personnel comprehensively instructed, highly trained and experienced. Regular refresher training established including appropriate record keeping.

Equipment and protective garments must either be decontaminated or properly contained for disposal before leaving the area.

Disposable protective equipment is to be decontaminated before removal (decontamination shower).

Open Handling Respiration : Full face mask (EN136)

Filter : P3 (EN143)

Eye : Yes, by face mask

Hand : Normal length chemical-mechanical-resistant gloves (EN374/EN388) worn over disposable gloves

Glove Material : Nitrile

Breakthrough time: 240 min

Thickness: 0.4 mm

Additional protection : Disposable dust-proof suit (EN465, type 4) worn over long underwear

Disposable boot covers, conductive

These values are derived from experiments, literature and information from the glove manufacturer.

They can also be derived from similar materials. In daily work please be aware that the using time depends on several

factors and can be shorter than the oficially tested permeation time.

Stability and reactivity

1 Reactivity

Reaction products with water

None known

2 Chemical stability

Hydrolysis : no data available

3 Possibility of hazardous reactions

Materials to avoid : oxidants

4 Conditions to avoid

Conditions to avoid : moisture

5 Hazardous decomposition products

Hazardous Decomposition Products

None, when used and handled as intended.

Disposal considerations

Waste treatment methods

Disposal Requirements Incineration in an approved, controlled furnace with combustion gas scrubbing and emission gas control.

Container Disposal